Sequencing 3 
Keysight M8195A Revision 2 – Arbitrary Waveform Generator User’s Guide    121 
 
3.7  Sequencer Execution Flow 
 
The given drawing shows an overview of the different trigger modes and the interaction 
with some of the conditional inputs.  
Programming
Waveform Download
Trigger Mode
Armed
Start First
Segment / Sequnce
Armed
Gate (Rising)
Enable
Armed
Self Armed
Y
N
Continuous
Gated
Triggered
Y
N
Self Armed
Armed
Enabled
Y
N
Armed
Trigger (Edge)
Self Armed
Armed
Enabled
Y
N
Segment / Sequence Generation
Y
N
Gate (Falling), End of Sequence (Triggered)
Stopped
RUN
Adv Event
Adv Event
 
Figure 30:  Sequencer execution flow 
 
 
RUN is moving the instrument from the programming mode to execution mode. 
Dependent on the selected trigger mode, the behavior in Armed mode is different. In 
trigger mode Continuous, the enable signal is used to control the execution of the first 
segment or sequence. In trigger mode Gated or Triggered, the enable is used as an 
additional start input.