EasyManua.ls Logo

Keysight M8195A - Source]:Stable:scenario:select[?] <Sequence_Table_Index>|Minimum|Maximum; Source]:Stable:scenario:advance[?] Auto|Conditional|Repeat|Single

Keysight M8195A
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 General Programming
234 Keysight M8195A Revision 2 Arbitrary Waveform Generator User’s Guide
6.18.8 [:SOURce]:STABle:SCENario:SELect[?]
<sequence_table_index>|MINimum|MAXimum
Command
:STAB:SCEN:SEL[?]
Long
:STABle:SCENario:SELect[?]
Parameters
<sequence_table_index>|MINimum|MAXimum
Parameter Suffix
None
Description
Select where in the sequence table the scenario starts in STSCenario mode.
Example
Command
:STAB:SCEN:SEL 0
Query
:STAB:SCEN:SEL?
6.18.9 [:SOURce]:STABle:SCENario:ADVance[?] AUTO|CONDitional|REPeat|SINGle
Command
:STAB:SCEN:ADV[?]
Long
:STABle:SCENario:ADVance[?]
Parameters
AUTO | COND | REP | SING
Parameter Suffix
None
Description
Set or query the advancement mode for scenarios.
Example
Command
:STAB:SCEN:ADV AUTO
Query
:STAB:SCEN:ADV?