EasyManua.ls Logo

Keysight M8195A - :OUTPut Subsystem

Keysight M8195A
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General Programming 6
Keysight M8195A Revision 2 Arbitrary Waveform Generator User’s Guide 207
6.13 :OUTPut Subsystem
6.13.1 :OUTPut[1|2|3|4][:STATe][?] OFF|ON|0|1
Command
:OUTP[?]
Long
:OUTPut[?]
Parameters
OFF|ON|0|1
Parameter Suffix
None
Description
Switch the amplifier of the output path for a channel on or off.
Example
Command
:OUTP ON
Query
:OUTP?
6.13.2 :OUTPut: ROSCillator:SOURce[?] INTernal|EXTernal|SCLK1|SCLK2
Command
:OUTP:ROSC:SOUR[?]
Long
:OUTPut:ROSCillator:SOURce[?]
Parameters
INTernal|EXTernal|SCLK1|SCLK2
Parameter Suffix
None
Description
Select which signal source is routed to the reference clock output:
INTernal: the module internal reference oscillator
EXTernal: the external reference clock from REF CLK IN with two variable
dividers
SCLK1: DAC sample clock with variable divider and variable delay
SCLK2: DAC sample clock with fixed divider

Table of Contents

Other manuals for Keysight M8195A

Related product manuals