2KJ/2KH
1-5-30
4. Remove the stop ring and bush from the
front of the machine.
5. Remove the scanner wire drum shaft from
the scanner unit.
Figure 1-5-51
6. Insert the locating ball on each of the scan-
ner wires into the hole in the respective
scanner wire drum and wind the scanner
wire three turns inward and four turns out-
ward.
With the locating ball as the reference point,
wind the shorter end of each of the wires
outward.
7. Secure the scanner wires using the scanner
wire stoppers.
Figure 1-5-52
Scanner wire drum shaft
Bush
Stop ring
Three turns
inward
Three turns
inward
Four turns
outward
Four turns
outward
Locating ball
Scanner wire
drum
Scanner wire
stopper
Scanner wire
stopper