2KJ/2KH-2
2-4-4
Section
Maintenance
part/location
User call 150K Points and cautions Page
Fuser
section
Fuser unit Check
Replace
- Replace if the problem occurs. P.1-5-47
Heat roller - Clean Clean with alcohol or a dry cloth. P.1-5-55
Press roller - Clean Clean with alcohol or a dry cloth. P.1-5-49
Heat roller separation
claw
Check
Replace
Clean Clean with alcohol.
Replace if claw is flawed, deformed or worn.
P.1-5-54
Section
Maintenance
part/location
User call 150K Points and cautions Page
Eject section Eject roller Check
Clean
- Clean it with alcohol if it is dirty.
Eject pulley Check
Clean
- Clean it with alcohol if it is dirty.
Switchback roller Check
Clean
- Clean it with alcohol if it is dirty.
Switchback pulley Check
Clean
- Clean it with alcohol if it is dirty.
Section
Maintenance
part/location
User call 150K Points and cautions Page
Covers Covers Clean Clean Clean with alcohol or a dry cloth.
Original cover Clean Clean Clean with alcohol or a dry cloth.
Section
Maintenance
part/location
User call 150K Points and cautions Page
Other Ozone filter Check
Clean
- Vacuum.
Image quality Check
Adjust
Check
Adjust