2KJ/2KH
1-3-3
High voltage U100 Setting the main high voltage
Grid control voltage
Copy interval
Copy quantity
Correction amount
107
*1
60
*1
50
*1
10
*1
U101
Setting the other high voltages
Setting the developing bias
Setting the transfer voltage
Setting the separation voltage
27/45/22/45
*1
123/126/33/31
*1
1/20/42/2
*1
U110 Checking the drum count -
Developing U130 Initial setting for the developing unit -
U144 Setting toner loading operation OFF/5/30
*1
U150 Checking sensors for toner -
U157 Checking/clearing the developing drive time -
U158 Checking the developing count -
Fuser and
cleaning
U161 Setting the fuser control temperature
Primary stabilization fixing temperature
Secondary stabilization fixing temperature
Copying operation temperature 1
Copying operation temperature 2
145
*1
165
*1
175
*1
185
*1
1
*1
2
*1
U162 Stabilizing fixing forcibly -
U163 Resetting the fuser problem data -
U167 Checking/clearing the fuser counts -
U198 Setting the fuser phase control OFF
*1,*2
U199 Checking the fuser temperature -
Operation
panel and
support
equipment
U200 Turning all LEDs on -
U202 Setting the KMAS host monitoring system -
U203 Checking DP operation -
U204 Setting the presence or absence of a key card or key counter OFF
*1,*2
U207 Checking the operation panel keys -
U233 Limiting job separator output MODE0
*1
U243 Checking the operation of the DP motors -
U244 Checking the DP switches -
U245 Checking messages -
U246 Setting the finisher 4/4/4
*1
U249 Checking the paper ejection to optional devices -
Mode setting U250 Setting the maintenance cycle 150000
*1,*2
U251 Checking/clearing the maintenance count -
U252 Setting the destination JAPAN
*1
U253 Switching between double and single counts DOUBLE COUNT
(A3/LEDGER)
*1,*2
U254 Turning auto start function ON/OFF ON
*1,*2
U260 Selecting the timing for copy counting EJECT
*1,*2
Section Item
No.
Content of maintenance item Initial
setting*