Page 190
MegaRAID SAS Software User GuideChapter 5: MegaRAID Command Tool
| Battery Backup Unit-Related Properties
5.11.3 Display BBU Capacity Use the command in the following table to display the BBU capacity for the selected
controller(s).
5.11.4 Display BBU Design
Parameters
Use the command in the following table to display BBU design parameters for the
selected controller(s).
Table 55: Display BBU Capacity Information
Convention MegaCli -AdpBbuCmd -GetBbuCapacityInfo
–aN|-a0,1,2|-aALL
Description Displays BBU capacity information. The information displays in the following
format:
BBU Capacity Info for Adapter: x
Relative State of Charge: xx%
Absolute State of Charge: xx%
Remaining Capacity: xx mAh
Full Charge Capacity: xx mAh
Run Time to Empty: xxx Min
Average Time to Empty: xxx Min
Average Time to Full: xxx Min
Cycle Count: xx
Max Error: xx%
Table 56: Display BBU Design Parameters
Convention MegaCli -AdpBbuCmd -GetBbuDesignInfo
–aN|-a0,1,2|-aALL
Description Displays information about the BBU design parameters. The information
displays in the following formats:
BBU Design Info for Adapter: x
Date of Manufacture: mm/dd, yyyy
Design Capacity: xxx mAh
Design Voltage: mV
Serial Number: 0xhhhh
Pack Stat Configuration: 0xhhhh
Manufacture Name: XXXXXX(String)
Device Name: XXXXXX(String)
Device Chemistry: XXXXXX(String)