Page 220
MegaRAID SAS Software User GuideChapter 5: MegaRAID Command Tool
| Dimmer Switch-Related Options
5.22.2 Sets the Properties on the
Selected Adapter
Use the command in the following table to set the Properties on the selected Adapter.
5.22.3 Displays the Power Saving
Level on the Virtual Disk
Use the command in the following table to display the power saving level on the virtual
disk.
Table 124: Sets the Properties on the selected Adapter
Convention MegaCLI -AdpSetProp{CacheFlushInterval -val}|{
RebuildRate -val}|{PatrolReadRate -val}| {BgiRate
-val}|{CCRate -val}|{ReconRate -val}|
{SpinupDriveCount -val}|{SpinupDelay -val}|
{CoercionMode -val}|{ClusterEnable -val}|
{PredFailPollInterval -val}|{BatWarnDsbl -val}
|{EccBucketSize -val}|{EccBucketLeakRate -val}
|{AbortCCOnError -val}|AlarmEnbl|AlarmDsbl|
AlarmSilence|{SMARTCpyBkEnbl -val}|
{SSDSMARTCpyBkEnbl -val}|NCQEnbl|NCQDsbl|
{MaintainPdFailHistoryEnbl -val}|
{RstrHotSpareOnInsert -val}|
{EnblSpinDownUnConfigDrvs -val}|{DisableOCR
-val}|{BootWithPinnedCache -val}|
AutoEnhancedImportEnbl|AutoEnhancedImportDsbl |
{CopyBackDsbl -val}|{AutoDetectBackPlaneDsbl
-val}|{LoadBalanceMode -val}|{UseFDEOnlyEncrypt
-val}|{DsblSpinDownHsp -val}|{SpinDownTime
-val}|{EnableJBOD -val} | {DsblCacheBypass
-val}|{useDiskActivityForLocate -val}|
{SpinUpEncDrvCnt -val}|{SpinUpEncDelay -val}
-aN|-a0,1,2|-aALL
Description Sets the properties on the selected adapter(s).
The possible settings are:
SpinUpEncDrvCnt: Max number of drives within an enclosure to spin up at
one time. Values: 0 to 255
SpinUpEncDelay: Number of seconds to delay among spinup groups within
an enclosure. Values: 0 to 255
Table 125: Displays the Power Saving Level on the Virtual Disk
Convention MegaSCU -LDSetPowerPolicy
-Default| -Automatic| -None|
-MaximumWithCaching|
-MaximumWithoutCaching
-Lx|-L0,1,2|-Lall
-aN|-a0,1,2|-aALL
Description Sets the power saving level on the virtual disk.