Page 310
MegaRAID SAS Software User GuideChapter 9: Monitoring System Events and Storage Devices
| Monitoring Rebuilds and Other
Processes
2. Select the BBU icon in the left panel.
The BBU properties appear in the right panel. The BBU properties include the following:
The number of times the BBU has been recharged (Cycle Count)
The full capacity of the BBU, plus the percentage of its current state of charge, and
the estimated time until it will be depleted
The current BBU temperature, voltage, current, and remaining capacity
If the battery is charging, the estimated time until it is fully charged
9.8.1 Battery Learn Cycle Learn Cycle is a battery calibration operation performed by the controller periodically
to determine the condition of the battery. You can start battery learn cycles manually or
automatically. To choose automatic battery learn cycles, enable automatic learn cycles.
To choose manual battery learn cycles, disable automatic learn cycles.
If you enable automatic learn cycles, you can delay the start of the learn cycles for up to
168 hours (7 days). If you disable automatic learn cycles, you can start the learn cycles
manually, and you can choose to receive a reminder to start a manual learn cycle.
9.8.1.1 Setting Learn Cycle
Properties
To set the learn cycle properties, perform the following steps:
1. Click the Physical tab to open the physical view.
2. Select the BBU icon in the left panel.
3. Click the Go To>BBU>Set Learn Cycle Properties.
The BBU operations screen appears.
4. On the BBU operations screen, click Enable automatic learn cycles and click Go.
You can delay the start of the next learn cycle by up to 7 days (168 hours) using the
Delay next learn cycle field.
5. To disable automatic learn cycles, click Disable automatic learn cycles and then
click Go.
You can start the learn cycles manually. In addition, you can check the box next to the
field Remind me when to start a learn cycle to receive a reminder to start a manual
learn cycle.
9.8.1.2 Starting a Learn Cycle
Manually
To start the learn cycle properties manually, perform the following steps:
1. Click the Physical tab to open the physical view.
2. Select the BBU icon in the left panel.
3. Click the Go To>BBU>Start Learn Cycle.
Another way to start the learn cycle is to right-click the BBU icon and select Start Learn
Cycle from the menu.
9.9 Monitoring Rebuilds and
Other Processes
MegaRAID Storage Manager software allows you to monitor the progress of rebuilds
and other lengthy operations in the Group Show Progress window.
Follow these steps to monitor the progress of these operations.
1. Open this window, shown in Figure192, by selecting Manage>Show Progress on
the menu bar.