EasyManuals Logo

Lenovo ThinkServer RD330 User Manual

Lenovo ThinkServer RD330
401 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #319 background imageLoading...
Page #319 background image
Page 319
MegaRAID SAS Software User Guide Chapter 10: Maintaining and Managing Storage Configurations
| Making a Drive Offline or
Missing
When the new drive spins up, the drive icon changes back to normal status, and the
rebuild process begins automatically. You can monitor the progress of the rebuild in
the Group Show Progress window by selecting Manage>Show Progress.
10.5 Making a Drive Offline or
Missing
If a drive is currently part of a redundant configuration and you want to use it in
another configuration, you can use MegaRAID Storage Manager commands to remove
the drive from the first configuration and change the drive state to Unconfigured Good.
CAUTION: After you perform this procedure, all data on that drive is lost.
To remove the drive from the configuration without harming the data on the virtual
drive, follow these steps:
1. In the MegaRAID Storage Manager main menu, click Go To>Physical Drive>Make
Drive (O)ffline.
The drive status changes to Offline.
2. Click Go To>Physical Drive>(M)ark Drive as Missing.
The drive status changes to Unconfigured Good.
CAUTION: After you perform this step, the data on this drive is no longer valid.
3. If necessary, create a hot spare drive for the virtual drive from which you have
removed the drive. (See Section8.3, Adding Hot Spare Drives.)
When a hot spare is available, the data on the virtual drive will be rebuilt. You can
now use the removed drive for another configuration.
CAUTION: If MegaRAID Storage Manager software detects that a drive in a virtual drive
has failed, it makes the drive offline. If this happens, you must remove the drive and
replace it. You cannot make the drive usable for another configuration by using the
Mark physical disk as missing and Rescan commands.
10.6 Upgrading the Firmware MegaRAID Storage Manager software enables you to easily upgrade the controller
firmware.
To avoid data loss because of dirty cache on the controller, the utility forces the virtual
disks into Write through mode after a firmware upgrade. It is in this mode until the
server reboots. In Write through mode, the controller sends a data transfer completion
signal to the host when the disk subsystem has received all the data in a transaction.
This way, in case of a power outage, the controller does not discard the dirty cache.
Follow these steps to upgrade the firmware:
1. In the MegaRAID Storage Manager main menu, click Go To>Controller>Update
Controller Firmware.
2. Click Browse to locate the .rom update file, as shown in Figure199.

Table of Contents

Other manuals for Lenovo ThinkServer RD330

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenovo ThinkServer RD330 and is the answer not in the manual?

Lenovo ThinkServer RD330 Specifications

General IconGeneral
Bus typeQPI
SteppingM1
FSB ParityNo
Scalability2S
Processor codeSR0LR
Processor cache10 MB
Processor cores4
Processor modelE5-2407
System bus rate6.4 GT/s
Processor seriesIntel Xeon E5-2400
Processor socketLGA 1356 (Socket B2)
Processor codenameSandy Bridge EN
Motherboard chipsetIntel® C606
Processor frequency2.2 GHz
Processor cache typeSmart Cache
Processor lithography32 nm
Processor manufacturerIntel
Processor package size45 x 42.5 mm
Processor front side bus- MHz
Processor operating modes64-bit
ECC supported by processorYes
Supported instruction setsAVX
Thermal Design Power (TDP)80 W
Number of processors installed1
Maximum number of SMP processors2
Maximum number of PCI Express lanes24
Memory types supported by processorDDR3-SDRAM
Memory channels supported by processorTriple
Memory clock speeds supported by processor800, 1066 MHz
Memory bandwidth supported by processor (max)25 GB/s
Maximum internal memory supported by processor375 GB
HDD size3.5 \
HDD interfaceSerial ATA, Serial Attached SCSI (SAS)
Optical drive typeDVD-RW
Total storage capacity0 GB
Maximum storage capacity12 TB
Number of HDDs installed0
Memory slots12
Internal memory4 GB
Memory clock speed1333 MHz
Maximum internal memory192 GB
Cabling technology10/100/1000Base-T(X)
Ethernet interface typeGigabit Ethernet
PS/2 ports quantity-
USB 2.0 ports quantity6
Ethernet LAN (RJ-45) ports3
Compatible operating systemsWindows Server 2012\\r Windows Server 2008\\r Windows Server 2008 R2\\r Windows Small Business Server 2011\\r Novel SUSE Linux Enterprise Server\\r VMware vSphere and VMware ESXi
Chassis typeRack (1U)
Power supply550 W
Sustainability certificatesENERGY STAR
PCI Express slots version3.0
Processor ARK ID64614
Intel Identity Protection Technology version0.00
Weight and Dimensions IconWeight and Dimensions
Depth734 mm
Width482.4 mm
Height43.6 mm
Weight17000 g

Related product manuals