Function library
Code table
9-258
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0070 VP SPEED CTRL 0.0 {0.5 } 255.0 V
pn
speed controller
Æ depending on C0086
Change of C0086 resets value to the assigned
default setting
C0071 TN SPEED CTRL 1.0 {0.5 ms} 600.0 T
nn
speed controller
>512 ms switched off
Æ depending on C0086
Change of C0086 resets value to the assigned
default setting
C0072 TD SPEED CTRL 0.0 0.0 {0.1 ms} 32.0 T
dn
speed controller
C0075 VP CURR CTRL 0.35 0.00 {0.01 } 15.99 V
pi
current controller
C0076 TN CURR CTRL 1.8 0.5 {0.1 ms} 2000.0 T
ni
current controller
2000 ms switched off
C0077 VP FIELD CTRL 0.25 0.00 {0.01 } 15.99 V
pF
field controller
C0078 TN FIELD CTRL 15.0 1.0 {0.5 ms} 8000.0 T
nF
field controller
8000 ms switched off
[C0081] MOT POWER 0.01 {0.01 kW} 150.00 Rated motor power acc. to nameplate
Æ depending on C0086
Change of C0086 resets value to the assigned
default setting
Change of C0081 sets C0086 = 0
[C0084] MOT RS 0.00 {0.01 Ω} 100.00 Motor stator resistance
Æ depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0085] MOT LS 0.00 {0.01 mH} 200.00 Motor leakage inductance
Æ depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0086] MOT TYPE See motor selection list Motor type selection
Æ depending on the controller used
Change of C0086 resets C0006, C0022, C0070,
C0071, C0081, C0084, C0085, C0087, C0088,
C0089, C0090, C0091 to the assigned default
setting
[C0087] MOT SPEED 300 {1 rpm} 16000 Rated motor speed
Æ depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0088] MOT CURRENT 0.5 {0.1 A} 300.0 Rated motor current
Æ depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0089] MOT FREQUENCY 10 {1 Hz} 1000 Rated motor frequency
[C0090] MOT VOLTAGE 50 {1 V} 500 Rated motor voltage
Æ depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0091] MOT COS PHI 0.50 {0.01 } 1.00 Motor cos ϕ
Æ depending on C0086
Change of C0086 resets value to the assigned
default setting
C0093 DRIVE IDENT 0
1
93xx
damaged power section
no power section
93xx
Controller identification
93xx: Lenze servo inverter
C0094 PASSWORD 0 0 {1} 9999 Password
Parameter access protection for the keypad XT.
If the password is activated, only the codes of
the user menu can be accessed. For further
possible selections see C0096