Function library
Code table
9-259
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
[C0095] ROTOR POS ADJ 0 0
1
Not active
Active
Rotor position adjustment of a synchronous
motor
C0058 displays the zero angle of the rotor
C0095 = 1 starts position adjustment
[C0096]
0
1
2
No password protection
Read protection
Write protection
Extended password protection for bus systems
with activated password (C0094).
All codes in the user menu can be accessed.
1 AIF PROTECT. 0
3
Read/write protection
AIF access protection
2 CAN PROTECT. 0 CAN access protection
C0099 S/W VERSION x.xx Software version
C0101 0.000 {0.001 s} 999.900
NSET
1 ADD-TIR 0.000
Additional acceleration for the main setpoint
2 ADD-TIR 0.000
(referring to speed variation of 0 ... n
max.
)
... ... ...
15 ADD-TIR 0.000
C0103 0.000 {0.001 s} 999.900
NSET
1 ADD-TIF 0.000
Additional deceleration times for the main
2 ADD-TIF 0.000
se
poin
... ... ...
e
e
ng
ospee
va
a
on o
... n
max.
15 ADD-TIF 0.000
C0105 QSP T IF 0.000 0.000 {0.001 s} 999.900 QSP deceleration time
Deceleration time for quick stop (QSP)
Ref. to speed change 0...n
max.
C0108 100.00 -199.99 {0.01 %} 199.99
FCOD (gain AOUT)
1 FCODE (GAIN)
2 FCODE (GAIN)
C0109
-199.99 {0.01 %} 199.99
FCODE (Offs.AOUT)
FCODE (OFFSET) 0.00
FCODE (OFFSET) 0.00
C0114 0
1
HIGH active
LOW active
DIGIN polarity
Terminal polarity
1 DIGIN1 POL 0 X5/E1
2 DIGIN2 POL 0 X5/E2
3 DIGIN3 POL 0 X5/E3
4 DIGIN4 POL 1 X5/E4
5 DIGIN5 POL 0 X5/E5
[C0116] → Selection list 2
Signal configuration FD0-xx
1 FDO-O0 1000 FIXED0
Free digital outputs can only be evaluated when
... ... ... ...
ne
wo
ed wi
hau
oma
ion in
e
aces.
32 FDO -31 1000 FIXED0
[C0117] → → Selection list 2 Signal configuration DIGOUT-x
Æ depending on C0005
1 DIGOUT1 15000 DCTRL-TRIP X5/A1
2 DIGOUT2 10650 CMP1-OUT X5/A2
3 DIGOUT3 500 DCTRL-RDY X5/A3
4 DIGOUT4 5003 MCTRL-MMAX X5/A4
C0118 0
1
High active
LOW active
DIGOUTx polarity
Terminal polarity
1 DIGOUT1 POL 1 X5/A1
2 DIGOUT2 POL 1 X5/A2
3 DIGOUT3 POL 0 X5/A3
4 DIGOUT4 POL 0 X5/A4
C0121 OH7 LIMIT 150 45 {1 °C} 150 Temperature for OH7
Threshold for motor temperature warning