Function library
Code table
9-260
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0122 OH4 LIMIT 85 45 {1 °C} 85 Temperature for OH4
Warning threshold - heatsink temperature
C0125 BAUD RATE 0 0
1
2
3
4
9600 baud
4800 baud
2400 baud
1200 baud
19200 baud
LECOM baud rate
LECOM baud rate for 2102 module
C0126 MONIT CE0 3 0
2
3
TRIP
Warning
Off
Conf. CE0
Configuration of communication error
monitoring with automation interface CE0
C0130 ACT TI NSET act. Ti times
active T
i
times of NSET
C0134 RFG CHARAC 0 0
1
linear
S-shaped
NSET RFG characteristic
Ramp characteristic for main setpoint
C0135 CONTROL WORD 0 0 {1} 65535 Control word
Controller control word for LECOM-A/B/LI or
operating module.
C0136
1 CTRLWORD C135 Control word C135
2 CTRLWORD CAN Control word CAN
3 CTRLWORD AIF Control word AIF
C0141 FCODE (SETPOINT) 0.0 -199.9 {0.1 } 199.9 Main setpoint
C0142 START OPTIONS 1 0
1
Start lock
Auto start
Start option
Start conditions are executed:
after mains connection
after message (t > 0.5s)
after TRIP
C0150 STATUS WORD 0 {1} 65535 Status word when networked with automation
interfaces
Binary interpretation indicates the bit states
C0151 FDO (DW) Display (hex.) of the free digital output signals
configured with C0116
Binary interpretation indicates the bit states
C0155 STATUS WORD 2
Bit00 Fail Bit08 R/L
Status word 2
Bit01 Mmax Bit09 –
Extended decimal status word
Bit02 Imax Bit10 –
Binary interpretation indicates the bit states
Bit03 IMP Bit11 –
Bit04 RDY Bit12 –
Bit05 CINH Bit13 –
Bit06 TRIP Bit14 –
Bit07 Init Bit15 –
[C0156] → Selection list 2
Configuration of the free bits of the status word
1 STAT.B0 2000 DCTRL-PAR*1-O
2 STAT.B2 5002 MCTRL-IMAX
3 STAT.B3 5003 MCTRL-MMAX
4 STAT.B4 5050 NSET-RFG I=O
5 STAT.B5 10650 CMP1-OUT
6 STAT.B14 505 DCTRL-CW/CCW
7 STAT.B15 500 DCTRL-RDY
C0157 (C0156) 0 1
C0161 ACT TRIP All fault indications Error message TRIP
Momentary fault indication (as under C0168/1)
C0167 RESET FAILMEM 0 0
1
No reset
Reset
History buffer reset
Clears the history buffer