Function library
Code table
9-262
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0183 DIAGNOSTICS
Drive diagnostics
Indicates fault or status information
If several items of fault or status information
aretobeshown,theinformationwiththe
smallest number is displayed
0 OK No fault
101 Initialisation Initialisation phase
102 TRIP/fault TRIP active
103 Emergency stop Emergency stop has been carried out
104 IMP message Message active
105 Power OFF
Function is not supported
111 BSP C135 operation inhibit
112 BSP AIF operation inhibit
Operation inhibited
113 BSP CAN operation inhibit
O
p
e
r
a
t
i
o
n
i
n
h
i
b
i
t
e
d
121 CINH terminal 28 controller inhibit Controller inhibited via X5/28
122 CINH internal 1 controller inhibit DCTRL-CINH1
123 CINH internal 2 controller inhibit DCTRL-CINH2
124 CINH C135/STOP controller inhibit STOP key at the keypad
125 CINH AIF controller inhibit Controller inhibited through AIF
126 CINH CAN controller inhibit Controller inhibited through CAN
141 Switch-on inhibit Restart protection active
142 IMP inhibit Pulse inhibit High resistance po wer outputs
151 QSP terminal Ext. quick stop QSP via MCTRL-QSP
152 QSP C135 quick stop QSP via STOP key at the keypad
153 QSP AIF quick stop QSP via AIF
154 QSP CAN quick stop QSP via system bus
250 Warning C168 Warning active
C0190 NSET ARIT 0 0
1
2
3
4
5
OUT = C46
C46 + C49
C46 - C49
C46 * C49
C46 / C49
C46/(100 - C49)
NSET
Arithmetic block in NSET function block.
Connects main setpoint C0046 and additional
setpoint C0040
C0195 BRK1 T ACT 99.9 0.0 {0.1 s} 99.9 BRK1
Brake closing time
Engagement time of the mechanical holding
brake
After the time elapsed under C0195, the status
”mechanical brake closed” is reached
C0196 BRK T RELEASE 0.0 0.0 {0.1 s} 60.0 BRK1
Brake opening time
Disengagement time of the mechanical holding
brake (see technical data of the brake).
After time has elapsed under C0195, the status
”mechanical brake closed” is reached
C0200 S/W ID Software ID
Software identification
C0201 S/W DATE Software generation
Creation date
C0203 COMM. NO. x / xxxx / xxxxx Commission number
C0204 SERIAL-NO. 0 {1} 65535 Serial number
C0207 DL INFO 1 Download info 1
C0208 DL INFO 2 Download info 2
C0209 DL INFO 3 Download info 3

Table of Contents