Function library
Code table
9-263
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0220 NSET TIR ADD 0.000 0.000 {0.001 s} 999.900 NSET
Additional setpoint Tir
Acceleration time T
ir
of the additional setpoint
for NSET
(referring to speed variation of 0 ... n
max.
)
C0221 NSET TIF ADD 0.000 0.000 {0.001 s} 999.900 NSET
Additional setpoint Tif
Deceleration time T
if
of the additional setpoint
for NSET
(referring to speed variation of 0 ... n
max.
)
C0222 PCTRL VP 1.0 0.1 {0.1 } 500.0 PCTRL
Vp gain
C0223 PCTRL TN 400 20 {1 ms} 99999 PCTRL
Integral component Tn
99999 ms: Switched off
C0224 PCTRL K D 0.0 0.0 {0.1 } 5.0 PCTRL
Kd differential component
C0241 NSET RFG-I = O 1.00 0.00 {0.01 %} 100.00 NSET
Threshold ramp function generator for main
setpoint
Input = output , (100 % = n
max
)
C0244 BRK M S ET 0.00 -100.00 {0.01 %} 100.00 BRK1
Holding torque of the DC injection brake
100 % = value of C0057
C0250 FCODE 1BIT 0 0
1
Lower limit
Upper limit
FCODE 1bit digital
C0252 ANGLE OFFSET 0 -245760000 {1 inc} 245760000 DFSET
Phase offset
Fixed phase offset for digital frequency
configuration
1 rev. = 65536 inc
C0253 ANGLE N-TRIM → -32767 {1 inc} 32767 DFSET
Speed-dependent phase trimming
Æ depending on C0005, C0025, C0490
Change of C0005, C0025, or C0490 resets
C0253 to the default setting
1 rev. = 65536 inc
C0253 is reached at 15000 rpm
C0254 VP ANGLE CTRL 0.4000 0.0000 {0.0001 } 3.9999 MCTRL
Vp phase controller
C0255 THRESHOLD P03 327680 10 {1 inc} 1800000000 Following error limit P03
1 rev. = 65536 inc
Following error > C0255 releases fault ”P03”
C0260 MPOT1 HIGH 100.00 -199.99 {0.01 %} 199.99 MPOT1
Upper limit (condition: C0260 > C0261)
C0261 MPOT1 LOW -100.0 -199.99 {0.01 %} 199.99 MPOT1
Lower limit (condition: C0261 < C0260)
C0262 MPOT1 T IR 10.0 0.1 {0.1 s} 6000.0 MPOT1
Acceleration time (referring to change
0 ... 100 %)
C0263 MPOT1 T IF 10.0 0.1 {0.1 s} 6000.0 MPOT1
Deceleration time (referring to change
0 ... 100 %)
C0264 MPOT1 ON/OFF 0 0
1
2
3
4
5
no change
Deceleration with T
if
to 0%
Deceleration with T
if
to C0261
Jump with T
if
=0to0%
Jump with T
if
= 0 to C0261
Acceleration with T
ir
to C0260
MPOT1
Deactivation function of motor pot
Function which is executed when motor pot is
deactivated via the input MPOT1-INACTIVE.