Function library
Code table
9-272
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0532 0-PULSE/TP 1 1
2
3
Index pulse
Touch probe
Index pulse and touch probe
DFSET
Selection of index pulse and/or touch p robe of
the feedback system
C0533 VP DENOM 1 1 {1} 32767 DFSET
Gain factor denominator
C0534 0PULSEFCT 0 0
1
2
10
11
12
13
Not active
Continuous
Cont. switchable
Once, fast way
Once, + direction
Once, - direction
Once, 2*zero pulse
DFSET
Zero pulse function
C0535 SET 0 DIV 1 1 {1} 16384 DFSET
Set zero pulse divider
C0536
-32767 {1} 32767
DFSET
1 VP-DIV
Absolute analog input signals
2 RAT-DIV
3 A-TRIM
C0537 N-TRIM -199.99 {0.01 %} 199.99 DFSET
Relative analog input signal
C0538
DFSET
1 0-PULSE
2 RESET
3 SET
C0539 IN -32767 {1 rpm} 32767 DFSET
C0540 FUNCTION 2 0
1
2
3
4
5
Analog input
Phase difference input
Resolver simulation - index pulse
Resolver simulation without index pulse
X10 = X9
X10 = X8
DFOUT
Function of the encoder outputs
X9 is inhibited, if 0, 1, 2 or 3 are selected
The input signals are buffered
[C0541] AN-IN 5001 MCTRL-NACT Selection list 1 DFOUT
Configuration - analog input signal
[C0542] DF-IN 1000 FIXEDPHI-0 Selection list 4 DFOUT
Configuration - master frequency input
[C0544] SYN-RDY 1000 FIXED0 Selection list 2 DFOUT
Synchronisation signal for the zero pulse
C0545 PH OFFSET 0 0 {1 inc} 65535 DFOUT
Phase offset
C0546 MIN INC/REV 1000 1 {1 inc} 2147483647 DFSET
Masking (suppressing) interference pulses at
X5/E4 (actual pulse of touch probe signal).
The size of the masking window between two
actual pulses is set.
C0547 (C0541) -199.99 {0.01 % } 199.99
C0548 (C0544) 0 1
C0549 (C0542) -32767 {1 rpm} 32767
C0551 MIN INC/REV 1000 1 {1 inc} 2147483647 DFSET
Masking (suppressing) interference pulses at
X5/E5 (set pulse of touch probe signal).
The size of the masking window between two
set pulses is set.
Code is available as of software version 6.2.