Function library
Code table
9-273
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0560 -199.99 {0.01 %} 199.99 FIXSET1
Fixed setpoints
1 FIX SET-VALUE 100
FIXSET1
2 FIX SET-VALUE 75
Fixed setpoints
3 FIX SET-VALUE 50
4 FIX SET-VALUE 25
5 FIX SET-VALUE 0
... ... ...
15 FIX SET-VALUE 0
[C0561] AIN 1000 FIXED0% →Selection list 1 FIXSET1
Configuration - analog input signal
[C0562] → Selection list 2
FIXSET1
1 IN1 1000 FIXED0
Configuration - digital input signals
2 IN2 1000 FIXED0
3 IN3 1000 FIXED0
4 IN4 1000 FIXED0
C0563 (C0561) -199.99 {0.01 % } 199.99
C0564 (C0562)
[C0570] IN 1000 FIXED0% →Selection list 1 S&H1
Configuration - analog input signal
[C0571] LOAD 1000 FIXED0 → Selection list 2 S&H1
Configuration - digital input signal
C0572 (C0570) -199.99 {0.01 % } 199.99
C0573 (C0571)
C0576 NERR WINDOW 100.00 0.00 {0.01 %} 100.00 Depending on C0011
Max. permissible system deviation between
actual speed and speed setpoint
C0577 VP FLD WEAK 3.00 0.00 {0.01] 15.99 Field weakening controller
V
pgain
C0578 TN FLD WEAK 50.0 2.0 {0.5 ms} 8192.0 Field weakening controller
Reset time Tn
C0578 = 8000 ms: Switched off
C0579 MONIT NEER 3 0
1
2
3
4
TRIP
Message
Warning
Off
Fault QSP
NEER monitoring
Configuration - speed monitoring
C0580 MONIT SD8 3 0
3
TRIP
Off
SD3 monitoring
Configuration - sine-cosine encoder monitoring
C0581 MONIT EER 0 0
1
2
3
TRIP
Message
Warning
Off
Monitoring EER
Configuration - monitoring of external faults
C0582 MONIT OH4 2 2
3
Warning
Off
OH4 monitoring
Configuration - heatsink temperature monitoring
C0583 MONIT OH3 → 0
3
TRIP
Off
OH3 monitoring
Configuration - ”fixed motor temperature”
monitoring
Æ depending on C0086
C0584 MONIT OH7 → 2
3
Warning
Off
OH7 monitoring
Configuration - ”adjustable motor temperature”
monitoring
Æ depending on C0086
Temperature monitoring via resolver input
C0585 MONIT OH8 3 0
2
3
TRIP
Warning
Off
Monitoring OH8
Configuration - ”adjustable motor temperature”
monitoring
Temperature monitoring via PTC input