Function library
Code table
9-274
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0586 MONIT SD2 0 0
2
3
TRIP
Warning
Off
Monitoring SD2
Configuration - resolver monitoring
C0587 MONIT SD3 3 0
2
3
TRIP
Warning
Off
Monitoring SD3
Configuration - ”Encoder at X9”
C0588 MONIT H10/H11 0 0
2
3
TRIP
Warning
Off
Monitoring H10 / H11
Configuration - ”temperature sensors in
controller” monitoring
C0589 MONIT P03 2 0
2
3
TRIP
Warning
Off
P03 monitoring
Configuration - following error monitoring
C0590 MONIT P13 0 0
2
3
TRIP
Warning
Off
P13 monitoring
Configuration - phase error monitoring
C0591 MONIT CE1 3 0
2
3
TRIP
Warning
Off
CE1 monitoring
Configuration - monitoring of ”CAN-IN1 fault”
C0592 MONIT CE2 3 0
2
3
TRIP
Warning
Off
CE2 monitoring
Configuration - ”CAN-IN2 error”monitoring
C0593 MONIT CE3 3 0
2
3
TRIP
Warning
Off
CE3 monitoring
Configuration - monitoring of ”CAN-IN3 fault”
C0594 MONIT SD6 → 0
2
3
TRIP
Warning
Off
SD6 monitoring
Configuration - monitoring of ”motor
temperature sensor”
Æ depending on C0086
C0595 MONIT CE4 3 0
2
3
TRIP
Warning
Off
CE4 monitoring
Configuration - ”CAN bus Off” monitoring
C0596 NMAX LIMIT 5500 0 {1 rpm} 16000 Speed monitoring
Configuration - monitoring of ”machine speed”
C0597 MONIT LP1 3 0
2
3
TRIP
Warning
Off
LP1monitoring
Configuration - monitoring of motor phase
failure
C0598 MONIT SD5 3 0
2
3
TRIP
Warning
Off
SD5 monitoring
Configuration - monitoring of ”master current at
X5/1.2 < 2 mA”
C0599 LIMIT LP 1 5.0 1.0 {0.1 %} 10.0 Current limit LP1
Current limit for motor phase failure monitoring
C0600 FUNCTION 1 0
1
2
3
4
5
OUT = IN1
IN1 + IN2
IN1 - IN2
IN1 * IN2
IN1 / IN2
IN1/(100% - IN2)
ARIT2
Function selection
[C0601] →Selection list 1
ARIT2
1 IN 1000 FIXED0%
Configuration - analog input signals
2 IN 1000 FIXED0%
C0602 (C0602) -199.99 {0.01 % } 199.99
[C0610] → Selection list 1
ADD1
1 IN 1000 FIXED0%
Configuration - analog input signals
2 IN 1000 FIXED0%
3 IN 1000 FIXED0%