EasyManua.ls Logo

Lenze EVS 9300 series - Page 416

Lenze EVS 9300 series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function library
Code table
9-290
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C1010 FUNCTION 1 0
1
2
3
13
14
21
22
OUT = IN1
IN1 + IN2
IN1 - IN2
IN1 * IN2 / 2
30
IN1 * IN2
IN1 / IN2
IN1 + IN2 (no limit)
IN1 - IN2 (no limit)
ARITPH1
Arithmetic function selection
[C1011] Selection list 3
ARITPH1
1 IN 1000 FIXED0INC
Input signal configuration
2 IN 1000 FIXED0INC
C1012
-2147483647 {1} 2147483647
1 (C1011/1)
2 (C1011/2)
[C1030] IN 1000 FIXEDPHI-0 Selection list 4 PHINT2
Input signal configuration
[C1031] RESET 1000 FIXED0 Selection list 2 PHINT2
Reset input
C1032 (C1030) -32767 {1 rpm} 32767
C1033 (C1031)
C1040 ACCELERATION 100.00 0.001 {0.001 } 5000.000 SRFG1
Setting of acceleration
C1041 JERK 0.200 0.001 {0.001 s} 999.999 SRFG1
Setting of jerk
[C1042] IN 1000 FIXED0% Selection list 1 SRFG1
Input signal configuration
[C1043] SET 1000 FIXED0% Selection list 1 SRFG1
Input signal configuration
[C1044] LOAD 1000 FIXED0 Selection list 2 SRFG1
Input signal configuration
C1045
-199.99 {0.01 %} 199.99
1 (C1042)
2 (C1043)
C1046 (C1044)
C1090 OUTPUT SIGNAL -2147483648 {1} 2147483647 FEVAN1
Signal output
C1091 CODE 141 2 {1} 2000 FEVAN1
Selection of the target code
C1092 SUBCODE 0 0 {1} 255 FEVAN1
Selection of the target subcode
C1093 NUMERATOR 1.0000 0.0001 {0.0001 } 100000.0000 FEVAN1
Numerator
C1094 DENOMINATOR 0.0001 0.0001 {0.0001 } 100000.0000 FEVAN1
Denominator
C1095 OFFSET 0 0 {1} 1000000000 FEVAN1
Offset setting
[C1096] IN 1000 FIXED0% Selection list 1 FEVAN1
Configuration - analog input signal
[C1097] LOAD 1000 FIXED0 Selection list 2 FEVAN1
Configuration - digital input signals
C1098 (C1096) -32768 {1} 32767
C1099 (C1097)
C1100 FUNCTION 1 1
2
Return
Hold
FCNT1
Function selection
[C1101] Selection list 1
FCNT1
1 LD-VAL 1000 FIXED0%
Configuration - analog input signals
2 CMP-VAL 1000 FIXED0%

Table of Contents

Related product manuals