Function library
Code table
9-290
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C1010 FUNCTION 1 0
1
2
3
13
14
21
22
OUT = IN1
IN1 + IN2
IN1 - IN2
IN1 * IN2 / 2
30
IN1 * IN2
IN1 / IN2
IN1 + IN2 (no limit)
IN1 - IN2 (no limit)
ARITPH1
Arithmetic function selection
[C1011] → Selection list 3
ARITPH1
1 IN 1000 FIXED0INC
Input signal configuration
2 IN 1000 FIXED0INC
C1012
-2147483647 {1} 2147483647
1 (C1011/1)
2 (C1011/2)
[C1030] IN 1000 FIXEDPHI-0 → Selection list 4 PHINT2
Input signal configuration
[C1031] RESET 1000 FIXED0 → Selection list 2 PHINT2
Reset input
C1032 (C1030) -32767 {1 rpm} 32767
C1033 (C1031)
C1040 ACCELERATION 100.00 0.001 {0.001 } 5000.000 SRFG1
Setting of acceleration
C1041 JERK 0.200 0.001 {0.001 s} 999.999 SRFG1
Setting of jerk
[C1042] IN 1000 FIXED0% →Selection list 1 SRFG1
Input signal configuration
[C1043] SET 1000 FIXED0% →Selection list 1 SRFG1
Input signal configuration
[C1044] LOAD 1000 FIXED0 → Selection list 2 SRFG1
Input signal configuration
C1045
-199.99 {0.01 %} 199.99
1 (C1042)
2 (C1043)
C1046 (C1044)
C1090 OUTPUT SIGNAL -2147483648 {1} 2147483647 FEVAN1
Signal output
C1091 CODE 141 2 {1} 2000 FEVAN1
Selection of the target code
C1092 SUBCODE 0 0 {1} 255 FEVAN1
Selection of the target subcode
C1093 NUMERATOR 1.0000 0.0001 {0.0001 } 100000.0000 FEVAN1
Numerator
C1094 DENOMINATOR 0.0001 0.0001 {0.0001 } 100000.0000 FEVAN1
Denominator
C1095 OFFSET 0 0 {1} 1000000000 FEVAN1
Offset setting
[C1096] IN 1000 FIXED0% →Selection list 1 FEVAN1
Configuration - analog input signal
[C1097] LOAD 1000 FIXED0 → Selection list 2 FEVAN1
Configuration - digital input signals
C1098 (C1096) -32768 {1} 32767
C1099 (C1097)
C1100 FUNCTION 1 1
2
Return
Hold
FCNT1
Function selection
[C1101] →Selection list 1
FCNT1
1 LD-VAL 1000 FIXED0%
Configuration - analog input signals
2 CMP-VAL 1000 FIXED0%