Lexmark MX310 - USB Wireless Cable Removal

Lexmark MX310
510 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Remove the scanner front cover. See “Scanner front cover removal” on page 386.
6 Remove the control panel assembly. See “Control panel assembly removal” on page 315.
7 Remove the UICC drip pan.
8 Remove the USB cable bracket. See “USB cable bracket removal” on page 320.
9 Feed the USB cable through the channel on the left side of the printer.
USB wireless cable removal
1 Remove the right cover. See “Right cover removal” on page 294.
2 Remove the RIP board shield. See “Controller board shield removal” on page 301.
3 Remove the fan.
4 Disconnect the MFP wireless cable from the RIP board.
5 Remove the scanner front cover. See “Scanner front cover removal” on page 386.
6 Remove the control panel assembly. See “Control panel assembly removal” on page 315.
7 Remove the UICC drip pan.
8 Lift the wireless control panel cover.
Note: For MX410 machines, two screws (A) must be removed to release the toroid from the cable.
7015
Parts removal
396