EasyManuals Logo

Linksys SPA9000 Administration Guide

Linksys SPA9000
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #121 background imageLoading...
Page #121 background image
Linksys Voice System Administration Guide 119
Localizing the SPA9000 Auto Attendant Prompts
Localization
Note The Auto Attendant prompt files must be encoded in G.711u and must
have a total file size (message and header) of 94.5 seconds or less.
1. Download the prompts:
a. Start Internet Explorer, enter the address of the EMEA Portal (www.linksys-voip.eu or
www.linksys-itsp.com), and log on.
b. In the left navigation pane, select the following links: FW & Tools > LVS > Localization
> SPA9000 Auto Attendant prompts.
c. Select the download link for the language that you want. Repeat as needed for up to
nine languages.
NOTE: North American partners can find localization files in the Utilities area of the Linksys
Partner Connection.
2. Store the downloaded files on a TFTP/HTTP/HTTPS server.
3. Configure the SPA9000 to download the files from the server:
a. Connect to the SPA9000 administration web server, and choose Admin access with
Advanced settings. (See Connecting to the SPA9000 Administration Web Server,” on
page 24).
b. Click Voice tab > the SIP tab.
c. Scroll down to the Auto Attendant Parameters area of the page.
d. In the AA Prompts URL field, enter the script for the server, path, and prompt file names.
SYNTAX:
serv=scheme://server_addr[:port]/root_path;[p1={prompt1 file path name};][p2={prompt2 file
path name};][p3={prompt3 file path name};][p4={prompt4 file path name};][p5={prompt5 file
path name};][p6={prompt6 file path name};][p7={prompt7 file path name};][p8={prompt8 file
path name};][p9={prompt9 file path name};][p10={prompt10 file path name};]
EXAMPLE:
serv=tftp://192.168.2.150/root/test/;p1=fr_1.wav; p2=fr_2.wav;p3=fr_3.wav;p4=none;
NOTE:
scheme: Enter one of the following values: tftp, http, or https.
port: The default ports are 69 for tftp, 80 for http, and 443 for https.
root_path can be empty.
[ ] denotes an optional item.
If the prompt file name is none, the corresponding prompt currently saved in the
flash is erased.

Table of Contents

Other manuals for Linksys SPA9000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Linksys SPA9000 and is the answer not in the manual?

Linksys SPA9000 Specifications

Physical Interfaces IconPhysical Interfaces
Ethernet ports2 10/100BaseT RJ-45
Phone ports2 RJ-11 FXS
Ring voltage40-55 VRMS
Ring frequency10 Hz - 40 Hz
Maximum ringer load3 REN
Power IconPower
On-hook voltage-50 V NOMINAL
Off-hook current25 mA min
Terminating impedanceConfigurable, including 600 ohms

Related product manuals