Linksys Voice System Administration Guide 94
Managing the Voice Mail Messages on the USB Key
Administering the SPA400 and Voice Mail Service
MailboxManageNumber: The Mailbox Manage Number that was entered on the SPA400
Voice mail Settings page. If you followed the instructions in the procedure “Configuring
the SPA400” on page_48, you set 800 as the Mailbox Manage Number.
•vmmN: Replace N with the number of the SPA9000 line interface (Line 1 ... Line 4) that is
configured for the SPA400 voice mail server.
5. Copy and paste the same string into the AA Dial Plan 2 field, for the purpose of allowing
remote access of voice mail at all times of day. For more information about AA Dial Plans,
refer to ”Configuring Dial Plans for the Auto Attendant,” on page 117.
6. Click Voice tab > Line N, where N is the number of the line interface for this SPA400 unit.
7. Make sure that the VMSP Bridge, XFER Bridge Mode, and CFWD Bridge Mode fields are set to
all.
8. Click Submit All Changes. The SPA9000 and the phones reboot.
9. To verify your progress, perform the following tasks:
a. Dial into the site from an external number.
b. When the Auto Attendant prompts you for an extension, press 8.
c. When the Voice Mail Server prompts for a mailbox number, enter the mailbox number.
d. When prompted for a password, enter the password.
Managing the Voice Mail Messages on the USB Key
To delete unneeded voice mail messages on the USB key, refer to the procedure below.
1. Connect to the SPA400 administration web server. (See ”Connecting to the SPA400
Administration Web Server,” on page 80.)
2. Click Administration tab > USB Setting.
3. Check the I want to reset USB check box.
4. Click Reset.

Table of Contents

Other manuals for Linksys SPA9000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Linksys SPA9000 and is the answer not in the manual?

Linksys SPA9000 Specifications

Physical Interfaces IconPhysical Interfaces
Ethernet ports2 10/100BaseT RJ-45
Phone ports2 RJ-11 FXS
Ring voltage40-55 VRMS
Ring frequency10 Hz - 40 Hz
Maximum ringer load3 REN
Power IconPower
On-hook voltage-50 V NOMINAL
Off-hook current25 mA min
Terminating impedanceConfigurable, including 600 ohms