Linksys Voice System Administration Guide 141
Advanced Topics for SPA400 Voice Mail Service
Configuring Outbound Call Codec Selection Codes
A user can enter a code selection code before dialing a number, to choose the preferred codec
for the associated call.The LVS is pre-configured with default codec selection codes, but you
can customize them for your site. The codes are automatically appended to the dial plan.
To select a specific codec per call, the phone user enters the code before entering the
telephone number.
1. Connect to the SPA9000 administration web server, and choose Admin access with
Advanced settings. (See ”Connecting to the SPA9000 Administration Web Server,” on
page 24).
2. Click Voice tab > Regional.
3. Scroll down to the Outbound Call Codec Selection Codes section.
SPA9000 Voice > Regional: Outbound Call Codec Selection Codes
4. Edit the codes, as needed.
5. Click Submit All Changes.
Advanced Topics for SPA400 Voice Mail Service
On the SPA9000, accessing a voicemail server to check or deposit voicemail is similar to calling
an external number, or being call forwarded to an external number. Each line interface can use
a different voicemail server.
There are three groups of voicemail operations:
Depositing voicemail
Managing voicemail from a client station or from an external number
Subscription to voicemail notification and receiving voicemail notification
SPA9000 assumes that a voicemail account can include more than one mailbox ID (MBID). The
voicemail account is defined with a user-ID, which can be the same as the line interface user-ID.

Table of Contents

Other manuals for Linksys SPA9000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Linksys SPA9000 and is the answer not in the manual?

Linksys SPA9000 Specifications

Physical Interfaces IconPhysical Interfaces
Ethernet ports2 10/100BaseT RJ-45
Phone ports2 RJ-11 FXS
Ring voltage40-55 VRMS
Ring frequency10 Hz - 40 Hz
Maximum ringer load3 REN
Power IconPower
On-hook voltage-50 V NOMINAL
Off-hook current25 mA min
Terminating impedanceConfigurable, including 600 ohms