Linksys Voice System Administration Guide 151
Remote Provisioning Features
Using the Resync URL
The SPA9000 can be configured to automatically resynchronize its internal configuration state
to a remote profile periodically and on power up. The automatic resyncs are controlled by
configuring the desired profile URL into the device.
Note The SPA resynchronizes only when it is idle.
SYNTAX:
http://spa-ip-addr/admin/resync?[[protocol://][server-name[:port]]/profile-pathname]
EXAMPLE: http://192.168.2.217/admin/resync?tftp://192.168.2.251/spaconf.cfg
•If no parameter follows /resync?, the Profile Rule setting from the Provisioning page is
used.
If no protocol is specified, TFTP is assumed. If no server-name is specified, the host that
requests the URL is used as server-name.
If no port is specified, the default port is used (69 for TFTP, 80 for HTTP, and 443 for
HTTPS).
The profile-path is the path to the new profile with which to resync.
Using the Reboot URL
You can use the Reboot URL to reboot the SPA9000.
Note The SPA9000 reboots only when it is idle.
SYNTAX:
http://spa-ip-addr/admin/reboot
EXAMPLE: http://192.168.2.217/admin/reboot

Table of Contents

Other manuals for Linksys SPA9000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Linksys SPA9000 and is the answer not in the manual?

Linksys SPA9000 Specifications

Physical Interfaces IconPhysical Interfaces
Ethernet ports2 10/100BaseT RJ-45
Phone ports2 RJ-11 FXS
Ring voltage40-55 VRMS
Ring frequency10 Hz - 40 Hz
Maximum ringer load3 REN
Power IconPower
On-hook voltage-50 V NOMINAL
Off-hook current25 mA min
Terminating impedanceConfigurable, including 600 ohms