Linksys Voice System Administration Guide 123
Configuring the SPA9000 and SPA9xx Call Progress Tones
Localization
Italy
Dial Tone
425@-10;*(0.2/0.2/1,0.6/1/1)
Outside Dial Tone
425@-16;10(0.2/0.2/1,0.6/1/1)
Prompt Tone
425@-19,620@-19;*(*/0/1+2)
Reorder Tone
425@-10;*(0.2/0.2/1)
Off Hook Warning Tone
425@-10;*(.2/.2/1,.2/.6/1)
Ring Back Tone
425@-10;*(1/4/1)
Busy Tone
425@-10;10(0.5/0.5/1)
Call Waiting Tone
425@-20;30(0.4/0.1/1,0.25/0.1/1,0.15/14/1)
Confirm Tone
425@-16;1(.25/.25/1)
Netherlands
Dial Tone
425@-10;*(*/0/1)
Outside Dial Tone
425@-16;10(*/0/1)
Prompt Tone
425@-19,620@-19;*(*/0/1+2)
Reorder Tone
425@-10;*(0.25/0.25/1)
Off Hook Warning Tone
425@-10;*(.2/.2/1,.2/.6/1)
Ring Back Tone
425@-10;*(1/4/1)
Busy Tone
425@-10;10(.5/.5/1)
Call Waiting Tone
425@-20;30(0.5/9.5/1)
Confirm Tone
425@-16;1(.25/.25/1)
Norway
Dial Tone
425@-10;*(*/0/1)
Outside Dial Tone
425@-16;10(*/0/1)
Prompt Tone
425@-19,620@-19;*(*/0/1+2)
Reorder Tone
425@-10;*(0.2/0.2/1)
Off Hook Warning Tone
1400@-10;*(0.4/15/1)
Ring Back Tone
425@-10;(1/4/1)
Busy Tone
425@-10;10(.5/.5/1)
Call Waiting Tone
425@-20;30(0.2/0.6/1,0.2/10/1)
Confirm Tone
1400@-16;1(20/0/1)

Table of Contents

Other manuals for Linksys SPA9000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Linksys SPA9000 and is the answer not in the manual?

Linksys SPA9000 Specifications

Physical Interfaces IconPhysical Interfaces
Ethernet ports2 10/100BaseT RJ-45
Phone ports2 RJ-11 FXS
Ring voltage40-55 VRMS
Ring frequency10 Hz - 40 Hz
Maximum ringer load3 REN
Power IconPower
On-hook voltage-50 V NOMINAL
Off-hook current25 mA min
Terminating impedanceConfigurable, including 600 ohms