NTP-004: Acceptance 363-206-285
Page6of6 Issue3,June2001
DDM-2000 OC-3 MULTIPLEXER
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
11. Perform end-to-end DS3 transmission test in the Mux direction for
each function unit group, if required.
DLP-511A. DS3 Single Ring Test in Mux Direction
DLP-553B. DS3 Dual Ring (DRI) Test in Mux Direction
DLP-511C. DS3 Single/Dual Homing Test in Mux Direction
DLP-54412. Perform end-to-end OC-3c (STS-3c) transmission test in the mux
direction, if required.
DLP-51613. Check local office alarm interface as required.
DLP-51914. Test protection switching function, if required.
15. The system is ready for service to be established.
DLP-51216. Activate remaining optional features as required.
DLP-511
DLP-553
DLP-544
DLP-516
DLP-519
DLP-512