TAP-108: Trouble Clearing 363-206-285
Page 1 of 2 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
Clear Obscure Failure Condition
1.
NOTE:
It is assumed that a set of alarms or conditions exist which are
inconsistent or may not have associated LEDs indications.
Perform LED test by depressing the ACO button or using the CIT command
test-led:.
Reference: DLP-509
2. Did any LED fail the LED test?
If YES, then do TAP-115.
If NO, then continue with Step 3.
3. Is a CIT available?
If YES, then proceed to Step 7.
If NO, then continue with Step 4.
4. Are there associated LED indications (for example, NE ACTY LED lighted; CR,
MJ, MN, PMN, etc. LED lighted when alarm is present, etc.)?
If YES, then continue with Step 5.
If NO, then proceed to Step 11.
5.
NOTE:
Unseating and reseating the SYSCTL performs a
reset
procedure which
restarts the software program.
Unseat and reseat SYSCTL circuit pack. Do not depress UPD/INIT button.
6. Is trouble still present?
If YES, then proceed to Step 9.
If NO, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
7. Use the CIT and reset command to reset SYSCTL.
DLP-509
TAP-115

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals