363-206-285 Detailed Level Procedure: DLP-532
Issue 2, February 2000 Page 4 of 14
DDM-2000 OC-3 MULTIPLEXER
5. Observe one of the following indications on the FE ID display. Note the
indication and follow the suggested procedure.
A. Letter "P" in FE ID Display
Indicates no software installed in SYSCTL. Software must be downloaded
locally using these procedures.
Continue with Step 6.
B. Letter "P." in FE ID Display
Indicates corrupted application software. New software must be force
downloaded locally using these procedures.
Proceed to Step 19.
C. FE ID Display Blank:
Indicates compatible software is installed in OHCTL and SYSCTL.This
procedure assumes the installed software version is not the correct
version. (Depress ACO button for longer than 2 seconds to display
software version on the FE ID display.)
Proceed to Step 9.
D. Letter "d" in FE ID Display:
Indicates OHCTL has no software or that software in OHCTL and
SYSCTL is incompatible.
Proceed to Step 19.
E. Letter "C" in FE ID Display:
Indicates software is installed in OHCTL and SYSCTL, but it will not
support the current shelf provisioning.
Proceed to Step 23.

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals