363-206-285 Detailed Level Procedure: DLP-532
Issue 2, February 2000 Page 14 of 14
DDM-2000 OC-3 MULTIPLEXER
36. Execute the apply: command at the shelf to receive the software.
Response: A "P" appears in the FE ID display when the installation
begins.
The SYSCTL resets after the software is installed.
LEDs and FE ID display go off on SYSCTL and User
Panel.
You are logged off the system.
After approximately 5 minutes you can log back into the
shelf and reestablish communications.
37. Was response correct?
If YES, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then continue with Step 38.
38. Did the letter "C" appear in the FE ID display?
If NO, then do Trouble Clearing: TAP-116.
If YES, then proceed to Step 23.