363-206-285 Detailed Level Procedure: DLP-562
Issue 2, February 2000 Page 3 of 12
DDM-2000 OC-3 MULTIPLEXER
NOTE:
When the ins-prog: or cpy-prog: command is used for software
upgrades from Release 9.1 or later, the software is loaded as a dormant
copy in the SYSCTL receiving the software. At the end of the download,
the rtrv-alm: report will show a status message of
dormant/exec code mismatch.Theapply: command must be
used to overwrite the original executing copy of software with the new
dormant software version. See the Commands and Reports section in
Volume 1 of this manual for a description of the TARP Release 13.0 and
15 apply: command.
Before performing this procedure, ensure that both TGS/TG3 circuit packs are
installed in the shelf receiving the program, then use the
switch-sync:s=circuitpack,pri=manual command to switch to the
protection TGS/TG3 circuit pack in TIMING slot 2, if not already ACTIVE.Use
rtrv-sync: command to verify that the protection TGS/TG3 circuit pack in
TIMING slot 2 is ACTIVE.
5.
NOTE:
If you want to load new software to a remote shelf (if allowed) directly
from a PC, use the ins-prog:tid or
ins-prog:tid,pgmtype=nesw command where the tid entered is
that of the remote shelf where you want to install the new software and
the pgmtype is the type of software you want to install. After using the
ins-prog:tid or ins-prog:tid,pgmtype=nesw command to
download software to one shelf, you must exit term (Alt F2)and
re-execute term before starting a second ins-prog: command. If
term is not exited, it will stop running if a second ins-prog: is started
within the same term session. The PC will not respond or return any
message and the ins-prog: will not progress.
NOTE:
If remote software downloading is allowed and you want to load new
software to a remote site via the DCC from a local shelf which already
contains the new software, log in (either locally or remotely) to the shelf
containing the new software, and then enter the cpy-prog:tid or
cpy-prog:tid,pgmtype=nesw command (where tid = the tid of the
shelf in which you want to install the software and the pgmtype is the type
of software you want to install). [Thetidisthenamegiventoashelf
(network element) using the set-ne: command.] The cpy-prog:
command will only copy software from a local controller to a remote
controller; it is not used to download software from a PC.

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals