M A E D A Mini-Crawler Crane Section 4 REMOTE CONTROL SYSTEM VERIFICATIONS
3/2019 MC305C-3 4-101
Checking Engine Emergency Stop Operation
1. When the engine is started as in the above
[1], try the Stop/EMO button to confirm that
the engine absolutely stops.
2. Here, check whether the indication as
"STOP" appears in the LCD screen.
Further, confirm that the Monitor display in
the Receiver shows the error code, "E1", at
that time.
Fig. 4-287
Checking "Outrigger Mode" Operation
WARNING!
Ensure that the boom and outriggers are in
the stow position, entirely.
In case where they are not in that position,
manipulate applicable levers of the Crane
to make them stowed.
Otherwise, the Transmitter operation may
cause damages to the boom or outriggers
or tipping the Crane that results serious
injury or death.
The Crane is inoperable in such event
where the LCD screen in the Transmitter
shows an error message or the Monitor
display in the Receiver shows an error
code.
Without fail, examine the cause of the error
and perform appropriate service when any
fault is identified, or contact us or our sales
service agency.
1. Position the Starter switch of the Crane to
ON.
2. Push the Power switch of the Transmitter to
power ON.
3. Turn ON the Main switch of the Receiver.
4. Switch the operation mode to the
"OUTRIGGER MODE" and confirm that
"Ground setting mode" is indicated in the
LCD screen.
Fig. 4-288
Fig. 4-289
5. Push the Speed/Mode button.
Here, confirm that the "Outrigger Extension
mode" is exhibited.