EasyManua.ls Logo

Megger MFT-X1 - Two-Pole Earth Resistance Testing

Megger MFT-X1
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.4 Safety, Hazard and Warning symbols on the instrument
This section details the various safety and hazard icons on the instruments outer case.
Icon Description
F
Warning: High Voltage, risk of electric shock
G
Caution: Refer to user guide
c
Equipment complies with current EU directives
Equipment complies with current UK conformity requirements
Equipment complies with Australian and New Zealand conformity requirements
Do not dispose of to landfill, sewage systems or by fire
t
Equipment protected throughout by double insulation or reinforced insulation
f
Terminal is fused
Do Not Open. No serviceable parts inside
Green LED indicates battery module is being charged
Refer to manual when red LED is lit
Lithium-Ion battery module connections
g
CAT IV
600 V
Category III 600 V measurement connection rating
g
CAT III
300 V
Category IV 300 V measurement connection rating
Follow local recycling guidelines for Lithium Ion batteries
>600 V
Do not use in distribution systems with voltages higher than 600 V AC RMS
2.5 Warning icons
This section details the warning icons that can show on the display.
Icon Warning Description
F
External Voltage Warning Hazardous voltage exists on measurement terminals
G
Internal Error Warning An error has occurred requiring attention
2.5.1 Connection terminals
This section relates to the explanation of the
Gsymbol on the top left of the terminal panel label:
Unmated terminals can be energized from within the instrument and from external connection of other terminals.
The current clamp must be the type indicated as “MCC1010” to ensure safe connection to the instrument.
www.megger.com MFT-X1
15
Safety Warnings

Table of Contents