15.5.10 PE confirmation ....................................................................................................................................81
15.5.11 Network connection .............................................................................................................................82
15.5.12 Clear network connection ....................................................................................................................82
15.5.13 Reset to factory settings .......................................................................................................................82
15.6 Continuity test settings R
LO .......................................................................................................................................................................................................... 83
15.6.1 Continuity buzzer threshold (limit alaram) ..............................................................................................83
15.7 Insulation resistance settings .................................................................................................................. 83
15.7.1 Live voltage limit ....................................................................................................................................83
15.7.2 Lock button available .............................................................................................................................84
15.7.3 Variable voltage .....................................................................................................................................84
15.7.4 Insulation buzzer threshold (limit alarm) .................................................................................................84
15.7.5 1000 V test ............................................................................................................................................84
15.8 Loop impedance settings ........................................................................................................................85
15.8.1 Allow reverse polarity ............................................................................................................................. 85
15.8.2 Maximum touch voltage ........................................................................................................................85
15.8.3 AUTO test start ......................................................................................................................................85
15.9 RCD test settings ......................................................................................................................................86
15.9.1 Allow reverse polarity ............................................................................................................................. 86
15.9.2 Maximum touch voltage ........................................................................................................................86
15.9.3 AUTO start test ......................................................................................................................................86
15.9.4 Ramp test speed ....................................................................................................................................86
15.9.5 Maximum test time ½ x I ........................................................................................................................87
15.9.6 Maximum test time 1 x I .........................................................................................................................87
15.9.7 Auto sequence customisation .................................................................................................................87
15.10 Instrument information ........................................................................................................................88
16. Download results to a remote device ..........................................................................................89
16.1 Creating a CertSuite™ account ..............................................................................................................89
16.2 Installing CertSuite™ on a mobile device .............................................................................................. 89
16.3 Switching on the MFT-X1 Bluetooth
®
mode .......................................................................................... 90
16.4 Connecting to the MFT-X1 from CertSuite™ ......................................................................................... 90
16.5 Failure to connect ....................................................................................................................................91
16.6 Sleep mode and power cycling the MFT-X1 ........................................................................................... 91
16.7 Sending test results to CertSuite™ .........................................................................................................92
16.8 Re-sending test results to CertSuite™ ....................................................................................................92
16.9 Further CertSuite information and support...........................................................................................92
www.megger.com
MFT-X1
8

Table of Contents

Other manuals for Megger MFT-X1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Megger MFT-X1 and is the answer not in the manual?

Megger MFT-X1 Specifications

General IconGeneral
Power SupplyRechargeable Li-ion battery
Phase Sequence IndicationYes
Resistance Range0.01 Ω to 100 kΩ
Protection RatingIP54
Continuity Testing0.01 Ω to 2000 Ω
Loop Testing0.01 Ω to 2000 Ω
RCD TestingType AC, A, F, B, and B+
Frequency Measurement15 Hz to 400 Hz
Insulation Test Voltage50 V, 100 V, 250 V, 500 V, 1000 V
Voltage Range12 V to 440 V AC/DC
Frequency Range15 Hz to 400 Hz
Battery LifeApproximately 8 hours