QX-830 Compact Industrial Scanner User’s Manual 5-51
Scanner Parameters
Serial Trigger
Allows the user to define the trigger character and delimiters that start and stop the read cycle.
A serial trigger is considered an online host command and requires the same command
format as all host commands. It must be entered within angle bracket delimiters < and >
or, in the case of non-delimited triggers, it must define individual start and stop characters.
Character (Delimited)
Allows the user to define the trigger character that initiates the read cycle.
A single ASCII host serial trigger character that initiates the read cycle.
A delimited trigger character is one that either starts or ends the read cycle and is
enclosed by delimiters such as < and >.
Note: Serial Data or Serial Data and Edge trigger mode must be enabled for Serial
Trigger Character to function.