QX-830 Compact Industrial Scanner User’s Manual 7-21
Utilities
Customer Default Parameters
Customer default parameters (saved by <Zc>) are the same set of parameters as power-on
parameters but are saved in a different, isolated section of NOVRAM. This allows a user
essentially to create a back-up set of parameters that can be recalled in the event that the
current parameters or power-on parameters have been accidentally changed or are no
longer desired.
It is important to note that a hardware default does not affect customer default parameters.
For example, a user that has inadvertently changed communication settings and saved
them with a <Z> command, may not know the correct settings or have the capability to
communicate within those settings. By first doing an EZ Button default to restore the
known Microscan
defaults, the user can then recall the previous customer-saved
settings
with an <Arc> or <Zrc> command.
Microscan Default Parameters
Microscan default parameters are contained in the firmware and cannot be changed.
Software Defaults
Microscan default parameters can be recalled (loaded into current settings) with the
<Ard> command or recalled and saved for power-on with the <Zrd> command.
Default on Power-On
Use the EZ Button to default the scanner by holding it down while applying power to the
scanner (if this feature is enabled).