QX-830 Compact Industrial Scanner User’s Manual 5-111
Scanner Parameters
Bad Symbol Message
Useful in determining if a symbol is present and if user defined requirements for that
symbol are met. Can tell the user if a qualified symbol is present but not decodable.
Sets the requirements that will qualify an object or a symbol before outputting a decode or
message. When enabled, sends a message to the host whenever an object meets the
qualifications setup but is not decoded.
Note: When Symbology Identifier is enabled, the Bad Symbol Message is preceded by
the identifier for the symbology being used.
Message
Any combination of ASCII characters can be defined as the Bad Symbol Message.