A-34 QX-830 Compact Industrial Scanner User’s Manual
Serial Commands
Configuration Database
Number of Active Indexes
Number of Active Indexes
Number of Database Cycles
Configuration Database
Index
Gain
AGC Mode
Tracking
Number of Active Indexes <K252,number of active indexes,number of database cycles>
Configuration Database
<K253,index,gain,AGC mode,tracking,unused,unused,unused, framing
status,laser on position,laser off position,laser power, background
color>
Switch Timing <K254,switch mode,time>
Serial Cmd: <K252,number of active indexes,number of database cycles>
Default: 0 (Disabled)
Options: 0 to 10
Serial Cmd: <K252,number of active indexes,number of database cycles>
Default: 0 (Disabled)
Options: 0 to 255
Serial Cmd:
<
K253,index
,gain,AGC mode,tracking,unused,unused,unused,framing status,
laser on position,laser off position,laser power,background color>
Options: 1 to 10 (database index number)
Serial Cmd:
<
K253,
index,
gain
,AGC mode,tracking,unused,unused,unused,framing status,
laser on position,laser off position,laser power,background color>
Default: 40
Options: 0 to 255
Serial Cmd:
<
K253,
index,gain,
AGC mode
,tracking,unused,unused,unused,framing status,
laser on position,laser off position,laser power,background color>
Default: 2 = Continuous
Options: 0 = Disabled 1 = Leading Edge 2 = Continuous
Serial Cmd:
<
K253,
index,gain,AGC mode,
tracking
,unused,unused,unused,framing status,
laser on position,laser off position,laser power,background color>
Default: 40
Options: 5 to 127