QX-830 Compact Industrial Scanner User’s Manual 2-17
Using ESP
Defaulting
When Default Current Menu Settings or Default all ESP Settings are selected, only the
ESP settings are defaulted.
Advanced Options
Send Current View
This is the same as
Save to Reader
>
Send No Save
except that only the
commands in the current configuration
tree are sent.
Send Current Command
This is the same as
Send Current
View
, except that it saves only the
command that is currently selected.
Add/Remove Exception
After a Receive Reader Settings command is performed
1
and the Add Exception option
is selected, a list of serial commands may appear. These are commands that may be in
the scanners firmware, but are not included in, or are different from, the current version of
ESP
.
These commands can be edited by double-clicking them and changing them as needed.
It is important to note that these commands will be saved to the scanner whenever a Save
to Reader command is sent, or when an <A> or a <Z> command is sent.
Also, if there is a corresponding ESP menu item, the ESP Value column for that item will
be blank following a Receive Reader Settings command.
1. From the Send/Recv button or by right-clicking in any blank section of a tree control view.

Table of Contents