7-22 QX-830 Compact Industrial Scanner User’s Manual
Scanner Status Requests
Scanner Status Requests
<K?> All Status Request
This is the fastest way to learn the scanners current configuration. Sending this request
will return the current settings of all commands, starting with the lowest K command value
and ending with the highest K command value.
<K??> All Descriptor Status Request
This request will return all current descriptors for every K command, starting with the lowest
K command value and ending with the highest K command value.
<K?#> All Range Status Request
This request will return the current settings of all commands within the user-defined range,
starting with the lowest user-defined K command value and ending with the highest
user-defined K command value.
<Knnn?> Single Status Request
This request will return the value of the variables associated with the requested K command.
The request of a single entry of a database command cannot exceed the number of database
slots for the specific command.
<Knnn??> Single Descriptor Status Request
This request returns the basic functional description of all fields in the requested K command.
<Knnn?#> Single Range Status Request
This request will return the value range and storage type description of all fields in the
requested K command.
<Knnnd> Default Customer Parameter
This request will default a single K command if the command has customer-defined
parameters rather than factory-defined parameters.