QX-830 Compact Industrial Scanner User’s Manual 5-91
Scanner Parameters
DataBar Limited
Note: DataBar Limited was previously known as “RSS Limited”.
DataBar Limited is designed to be read by laser scanners and CCD imagers. It is not
recommended for omnidirectional slot scanners.
Encodes a smaller 14-digit symbol (74 modules wide) that is not omnidirectional.
DataBar Omnidirectional
Note: DataBar Omnidirectional was previously known as “RSS-14”.
Used in the grocery, retail, and prescription drug industries where 14-digit EAN item
identification may be needed.
DataBar-14 is a fixed symbol length symbology that encodes 14 digits, including a 1-digit
indicator. DataBar-14 is 96 modules wide. It can be stacked in two rows, it can read
omnidirectionally if printed in full height, or horizontally if height-truncated for small marking.
Note: Where appropriate, use 1 (non-stacked) for better performance instead of 2
(stacked; decode both stacked and non-stacked).