QX-830 Compact Industrial Scanner User’s Manual 5-115
Scanner Parameters
Static Presentation
Static Presentation Mode is used in conjunction with Continuous Read mode.
When operating in Static Presentation Mode, the red LEDs will illuminate while the
scanner is searching for a symbol in Continuous Read mode. When a symbol is placed
in the field of view and a good read occurs, the green LEDs will illuminate and stay on for
the duration of time set in Green Flash Duration. Only one read will occur during that time
unless more than one symbol is enabled in Number of Symbols.
Note: If Static Presentation Mode is selected but the scanner is not in Continuous
Read, the Green Flash will not occur.
To use Static Presentation:
1. Enable Continuous Read.
2. Select the number of symbols.
3. Enable Static Presentation in Green Flash Mode.
4. Select the read time in Green Flash Duration.
Match
The green LEDs will flash when a match condition is met. If multisymbol is enabled, then
green flash LEDs will illuminate only if all symbols qualify as a match. If matchcode is
disabled, then this mode will activate the LEDs on a good read.
Mismatch
Same as Match, except that LEDs will illuminate on a mismatch.