QX-830 Compact Industrial Scanner User’s Manual A-61
Appendices
Wild Card Character
Sequence on No Read
Sequence on Mismatch
Master Symbol Database Size
New Master Pin
Sequence Step
Master Symbol
Index
Master Symbol Data
Serial Cmd: <K223,matchcode type,sequential matching,match start position,match
length,
wild card character
,sequence on No Read,sequence on mismatch>
Default: * (asterisk)
Options: Any 7-bit ASCII character
Serial Cmd: <K223,matchcode type,sequential matching,match start position,match
length,wild card character,
sequence on No Read
,sequence on mismatch>
Default: 1 = Enabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K223,matchcode type,sequential matching,match start position,match
length,wild card character,sequence on No Read,
sequence on mismatch
>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K224,
number of master symbols
>
Default: 1
Options: 1 to 10
Serial Cmd: <K225,status>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K228,sequence step>
Default: 1
Options: 1 to 32768
Serial Cmd: <K231,index,master symbol data>
Options: 1 to 32768
Serial Cmd: <K231,index,master symbol data>
Options: Any valid ASCII string