A-70 QX-830 Compact Industrial Scanner User’s Manual
Serial Commands
Serial Utility Commands
Type Command Name
Read Rate
<C> Enter Decodes/Second Test
<Cp> Enter Decode Percent Test
<J> Exit Decodes/Second and Decode Percent Tests
<a1> PDF417 Information
Counters
<N> No Read Counter
<O> No Read Counter Reset
<T> Trigger Counter
<U> Trigger Counter Reset
<V> Good Read/Match Counter
<W> Good Read/Match Counter Reset
<X> Mismatch Counter
<Y> Mismatch Counter Reset
Device Control
<L1> Programmable Output 1
<L2> Programmable Output 2
<L3> Programmable Output 3
<I> Disable Scanner
<H> Enable Scanner
<G> Store Next Symbol Read to Database Index 1
Master Database <Gn> Store Next Symbol Read to Database Index n
<NEWM> New Master Load Status
Part Number /
Checksum
<#> Display All Firmware Part Numbers
<#a> Display Application Code Part Number
<#b> Display Boot Code Part Number
<#f> Display FPGA Code Part Number
<!> Display All Available Firmware Checksums
<!a> Display Application Code Code Checksum
<!b> Display Boot Code Checksum
<!f> Display FPGA Code Checksum
<Z> Save Current Settings for Power-On
<Zc>
Save Current Settings as Customer Default Parameters
for Power-On
<Zrc>
Recall Customer Default Settings and Save for
Power-On
Default/Reset/Save
<Zrd>
Recall Microscan Default Settings and Save for
Power-On (Will not default “sticky settings”)
<Zrdall>
Recall Microscan Default Settings and Save for
Power-On (Will also default “sticky settings”)
<A> Reset (Will not save for power-on)
<Arp> Reset and Recall Power-On Parameters