A-76 QX-830 Compact Industrial Scanner User’s Manual
Protocol Commands
Setup 4
Transfer 1
Transfer 2
Error Condition
Transfer 1
RES 0x21 ‘!’
REQ 0x3D ‘=’
STX 0x28 ‘(‘
ETX 0x29 ‘)’
ACK 0x06
NAK 0x15
LRC enabled
HOST_TX (<K141,0>)H
SCANNER_TX ‘ACK’
HOST_TX (<K100?>)n
SCANNER_TX ‘ACK’
HOST_TX ‘!’
SCANNER_TX (<K100,8,0,0,1>)X
HOST_TX ‘ACK’
SCANNER_TX ‘!’
HOST_TX (<K141,0>)H
SCANNER_TX ‘ACK’
HOST_TX (<K100?>)n
SCANNER_TX ‘ACK’
HOST_TX ‘!’
SCANNER_TX (<K100,8,0,0,1>)X
timeout reached...
SCANNER_TX ‘=’
timeout reached...
SCANNER_TX ‘=’
timeout reached...
SCANNER_TX ‘=’
timeout reached...
SCANNER_TX ‘!’