– 3.9 –
• The clamp lever has
been lowered without
media placed.
• If roll paper is being
used, it indicates that
the media has run out.
• If the entire LCD
display flashes in
REMOTE mode, it
indicates that data
have not been
received for 30
seconds or more.
• If indicates that the
battery has run out.
1) Place media first, then lower the
clamp lever.
2) If the error occurs with media loaded
on the machine, conduct sensor tests
to find out a possible cause of the
trouble.
Possible causes of the trouble are as
follows:
a) The sheet sensor has failed.
b) The IO PCB has failed.
c) The main PCB has failed.
1) Confirm that the computer is sending
data.
2) Replace the I/F cable with a new one.
3) Replace the 1394 PCB.
4) Replace the main PCB.
1) Replace the battery with a same type.
(CR2032)
Message Description
Corrective measures and
recovering procedures
* REMOTE *
BATTERY EXCHANGE
< LOCAL >
* * NO MEDIA * *