– 3.8 –
•The power of heater
is off.
• The preheater is
disconnected.
• The operating voltage is
100 to 200 VAC but the
voltage selector of the
heater is set to 220 V.
• The printheater is
disconnected.
• The operating voltage is
100 to 200 VAC but the
voltage selector of the
heater is set to 220 V.
• The thermistor of the
preheater is defective.
• The thermistor of the
printheater is
defective.
•The nozzle recovery
cannot be expected
because the device is
left for a prolonged
period of time.
• The number of times
of use of the wiper has
been exceeded.
• The ID numbers of
heads have not been
inputted.
1) Turn on the power of the heater.
1) Set the voltage selector to the correct
voltage.
2) Replace the printheater.
3) Replace the fuse if blown.
1) Replace the thermistor.
2) Replace the IO2 PCB.
3) Replace the main PCB.
1) Make test plotting.
If nozzle missing is serious, execute
[STATION] - [WASH] for
maintenance.
1) Replace the wiper.
1) Input the ID numbers of heads.
Message Description
Corrective measures and
recovering procedures
Heater Power OFF
Pre BREAKAGE
Print 40° C ( 4 5)
Pre 43° C ( 4 7)
Print THERMISTOR
Pre 43° C ( 4 7)
Print BREAKAGE
Pre THERMISTOR
Print 40° C ( 4 5)
< LOCAL >
DO TEST DRAW
< LOCAL >
REPLACE WIPER
< LOCAL >
HEAD ID Un - input