Warning / Error Messages
6-13
1
1
1
1
6
Troubleshooting
Message Cause Solution
An abnormality occurs in the heavy-
duty feeding device.
Once turn OFF the power supply and
after a while, turn it ON again.
If the error message is displayed
again, contact our service and sales
office.
The ambient temperature is out of
the usable temperature range (too
low).
Adjust the ambient temperature of the
installation place. ( P.3-39)
The ambient temperature is out of
the usable temperature range (too
high).
There is a slot where no cartridge
has been inserted.
Set a cartridge.
An error occurred on the head unit
memory.
Turn off the main power to the
machine and turn it on after a while.
If the same error message appears
again, contact your local distributor to
call for service.
The head is not connected.
An error occurred on the head slider
board.
The head is not MIMAKI genuine.
A SD-RAM of the size required for
the machine has not been
equipped.
Turn off the main power to the
machine and turn it on after a while.
If the same error message appears
again, contact your local distributor to
call for service.
(When a usable SD-RAM is available,
the machine can be started as is.
However, a printing speed may be
slow depending on resolution. )
A SD-RAM of the size required for
the machine has not been
equipped.
Turn off the main power to the
machine and turn it on after a while.
If the same error message appears
again, contact your local distributor to
call for service.
An error is detected on the wave-
form printed on the lower line of the
display.
Turn off the main power to the
machine and turn it on after a while.
If the same error message appears
again, contact your local distributor to
call for service.
Model ID of main PCB is different.
(XX is ID code.)
An abnormal temperature of the
media heater was detected.
An error was detected during scan-
ning operation.
Turn off the main power to the
machine and turn it on after a while.
If the same error message appears
again, contact your local distributor to
call for service.
A system error occurred.
***** ERROR 67 *****
FEEDER UN I T 0 4
**** ERROR 120 ****
ENV I RONMENT TEMP ( LO )
**** ERROR 121 ****
ENV I RONMENT TEMP ( H I )
**** ERROR 144 ****
CARTR I DGE SET !
**** ERROR 200 ****
HEAD MEMORY (----)
**** ERROR 202 ****
DVE I CE CONSTRUCT I ON
**** ERROR 203 ****
SDRAM S I ZE
**** ERROR 205 ****
42V HEAD Vo l t age
**** ERROR 207 ****
XXXXXXXXXX
**** ERROR 208 ****
CHECK MA I N PCB I D XX
**** ERROR 211 ****
HeaterTEMP(--/--/--)
**** ERROR 250 ****
YCOORDINATES
**** ERROR 251 ****
SYSTEM ERROR