1 stations occupied (Master CSD-892-73)
Device No. Contents Classication
RYn0 ZERO
Control signal
RYn1 ZERO Clear
RYn2 Tare weight cancellation
RYn3 Tare weight cancellation clear
RYn4 Hold
RYn5
RYn6
RYn7 Indicate value changeover ag (Net value/Gross value)
RYn8
RYn9
RYnA
RYnB
RYnC
RYnD
RYnE
RYnF
RY(n+1)0
System reservation zone
RY(n+1)1
RY(n+1)2
RY(n+1)3
RY(n+1)4
RY(n+1)5
RY(n+1)6
RY(n+1)7
RY(n+1)8
RY(n+1)9 Initialed data
setting request ag
RY(n+1)A Error reset requesting ag
RY(n+1)B
RY(n+1)C
RY(n+1)D
RY(n+1)E
RY(n+1)F
n : Value decided by setting of station No.
* Error reset is operated by main body side because error cancellation request ag is not
dened in 1 occupied station. (Synchronize with reset of the main body.)
Setting value writing request (Request 1)
Writing of the data set in special data area (RWwn0 ~ RWwnB) is requested
ON In the request of writing
OFF After conrming [Setting value writing response (Response 1)]
General command request (Request 2)
Writing or reading out is requested by the command order.
Use with selection of writing or reading out (R/W) at the same time.
ON In the request of writing/reading out
OFF After conrming [Setting value writing response (Response 2)]