2) Remote register of 5 steps comparator mode
4 stations occupied (Master CSD-892-73
Station Remote register Contents Remarks
1
RWwn
S1 (32 bit)
Special data area
RWwn+1
RWwn+2
S2 (32 bit)
RWwn+3
2
RWwn+4
S3 (32 bit)
RWwn+5
RWwn+6
S4 (32 bit)
RWwn+7
3
RWwn+8
Full (32 bit)
RWwn+9
RWwn+A
Near zero (32 bit)
RWwn+B
4
RWwn+C
General data area
RWwn+D
RWwn+E Command No. (Return)
RWwn+F Operating mode (Return)
n : Value decided by setting of station No.      
2 stations occupied (Master CSD-892-73)
Station Remote register Contents Remarks
1
RWwn
S1 (32 bit)
Special data area
RWwn+1
RWwn+2
S2 (32 bit)
RWwn+3
2
RWwn+4
General data area
RWwn+5
RWwn+6 Command No. (Return)
RWwn+7 Operating mode (Return)
n : Value decided by setting of station No.
1 station occupied (Master CSD-892-73)
Station Remote resister Contents Remarks
1
RWwn
Undened
RWwn+1
RWwn+2
RWwn+3
n : Value decided by setting of station No.
    
Please change by using the general command request (Request 2) when you
change S0
Please set the stored place to [Internal RAM] when the set data is continuously
changed, and the rewritable time of [EEPROM] might exceed about one million
times.
Please do not change in the set value under the measurement because the A/
D sampling rate decreases temporarily while rewriting the set value when the
stored place of set data is [EEPROM]. Please set the stored place to Internal
[RAM] if you change the set value under the measurement. Please refer to [6-10.
Change of data stored place] for the details of setting method of stored place.
83