EasyManua.ls Logo

Minolta Di251 - Page 222

Minolta Di251
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FrameMaker Ver.5.5E(PC) Di251/Di351 DIS/REASSEMBLY, ADJUSTMENT
05.03.01
D-41
(5) Registration (CD) (Printer)
Adjust so that width A on the test pattern produced falls within the following range.
Requirement
NOTE
This adjustment must be made when the PH Unit has been replaced and, for 2-sided,
after Registration (CD) (Printer) for each paper source for 1-sided and Registration (FD)
(Printer) have been made.
Adjustment Procedure
1. Call the Adjust Mode to the screen.
2. Touch "Printer" and "Registration (CD)", in that order.
3. 1-Sided: Touch "Test Print" and select the paper source, for which the adjustment is to
be made.
2-Sided: Touch "Test Print" and select "Duplex".
At this time, the 1st Drawer is selected.
4. Press the Start key.
A test pattern will be produced.
5. 1-Sided: Check to see if width A on the test pattern meets the specifications.
2-Sided: Check to see if width A on the second side of the 2-sided copy meets
the specifications. If width A falls outside the specified range, perform the fol-
lowing steps for adjustment.
6. Touch "END" to recall the Registration (CD) screen.
7. Selectthepapersourceselectedinstep3.
8. Press the Clear key to clear the current setting value.
Specification Adjust Mode Setting Range
1-Sided: 10 ±2.0 mm
2-Sided: 10 ±3.0 mm
Registration (CD) -4.0 to +4.0
A
TEST PRINT
X
TEST PRINT
X
A
4658D512AA
1-Side
4661D501AA
2-Sided

Table of Contents

Other manuals for Minolta Di251

Related product manuals